CW-M SERIES
AC POWER SOURCE
Operation Manual
This manual covers models:
CW 801M
CW 1251M
CW 2501M
©2002 by Elgar Electronics Corporation
This document contains information proprietary to Elgar Electronics Corporation. The information contained herein is
not to be duplicated or transferred in any manner without prior written permission from Elgar Electronics Corporation.
March 8, 2002 Document No. M161570-01 Rev E
Seitenansicht 0
1 2 3 4 5 6 ... 47 48

Inhaltsverzeichnis

Seite 1 - AC POWER SOURCE

ELGAR ELECTRONICS CORPORATION 9250 Brown Deer Road San Diego, CA 92121-2294 1-800-733-5427 Tel: (858) 450-0085 Fax: (858) 458-0267 Email: sales@elga

Seite 2

Elgar CW-M Series 5 OPERATION...33 5.1 Parallel and Multiphase Operation ...

Seite 3

Elgar CW-M Series 1 INTRODUCTION Elgar's ContinuousWave™ (CW) Series power sources deliver up to 1250 VA in a 2U high (3.5 inches) rackmount chas

Seite 4

Elgar CW-M Series This page intentionally left blank. 2

Seite 5 - YEAR WARRANTY

Elgar CW-M Series 2 SPECIFICATIONS Note: Product specifications are subject to change without notice. 2.1 Output Power CW 801M: 800 VA CW 1251M: 1250

Seite 6

Elgar CW-M Series Frequency Range: 45 to 500 Hz Accuracy: ±0.5% typical Resolution: 0.1 Hz 2.3 Measurement Voltage Range: 0 to 135/270 VRMS Accuracy:

Seite 7 - SAFETY NOTICE

Elgar CW-M Series Meter Select switch: Current/frequency select Output Voltage: Adjusted using 10–turn potentiometer Output Current: Adjusted using 10

Seite 8 - SAFETY SYMBOLS

Elgar CW-M Series 2.5 Rear Panel Connections Input Connector: Covered barrier terminal strip with strain relief Output Connector: Covered barrier te

Seite 9 - CONTENTS

Elgar CW-M Series 2.7 General Dimensions CW 801M: 3.5" H (89 mm) x 19" W (483 mm) x 20.6" D (524 mm) CW 1251M: 3.5" H (89 mm) x 19

Seite 10 - LIST OF TABLES

Elgar CW-M Series 2.8 Options and Accessories L: Locking knobs (front panel potentiometers) Rack Slide Kit (Elgar part number K161570-01) Parallel C

Seite 11 - 1 INTRODUCTION

Elgar CW-M Series 3 INSTALLATION The Elgar CW series power supply has been fully calibrated and tested prior to shipment. The instrument is ready for

Seite 13 - 2 SPECIFICATIONS

Elgar CW-M Series 3.2 Wire Gauge Selection The following guidelines assist in determining the optimum cable specification for your power application

Seite 14 - 2.4 Front Panel

Elgar CW-M Series The following notes apply to Table 3–1 and to the power cable definition: 1. The above figures are based upon insulated copper cond

Seite 15

Elgar CW-M Series 4. Derate the above wire gauge (use a heavier gauge) for higher environmental temperatures since conductor resistance increases wit

Seite 16 - 2.6 Input

Elgar CW-M Series 3.3 Mounting Instructions Refer to Figure 3–1 through Figure 3–4 for mounting dimensions and other installation information for the

Seite 17 - 2.7 General

Elgar CW-M Series Figure 3–2 Mounting Dimensions, Front and Rear Views (CW 801M, CW 1251M) 14

Seite 18

Elgar CW-M Series Figure 3–3 Mounting Dimensions, Front and Rear Views (CW 2501M) 15

Seite 19 - 3 INSTALLATION

Elgar CW-M Series Figure 3–4 Mounting Dimensions, Top and Side Views (CW 801M, CW 1251M) 16

Seite 20 - 3.2 Wire Gauge Selection

Elgar CW-M Series Figure 3–5 Mounting Dimensions, Top and Side Views (CW 2501M) 17

Seite 21

Elgar CW-M Series 3.5 Power In Connections Connect input power to the INPUT terminal block on the rear panel as specified below. Refer to Figure 3–6.

Seite 22

Elgar CW-M Series 3.5.2 Split–Phase Supply Connections 120–0–120V 1. Remove the protective cover from the terminal block. 2. Route the cables throug

Seite 24

Elgar CW-M Series 3.6 Power Out Connections 1. Remove the protective cover from the terminal block. 2. A factory jumper has been added to connect N

Seite 25

Elgar CW-M Series 21 3.7 Sense Connections The CW Series unit can be used with or without remote sense leads connected to the load. Where the sense

Seite 26

Elgar CW-M Series To utilize remote sensing at the user's load, follow these steps: 1. Remove the protective cover from the terminal block. 2.

Seite 27

Elgar CW-M Series 3.8 Parallel Connected Units To achieve higher output power than what is available from one unit, you can connect up to six units in

Seite 28 - 3.5 Power In Connections

Elgar CW-M Series This page intentionally left blank. 24

Seite 29

Elgar CW-M Series 4 SET-UP Once installation is complete and all cable connections are secure, check the settings on the 12-position CONFIG dipswitch

Seite 30 - 3.6 Power Out Connections

Elgar CW-M Series Switch Position Function ON Required to enable current master and slave operation 1,2 OFF Stand-alone unit or phase slave ON Curr

Seite 31 - 3.7 Sense Connections

Elgar CW-M Series 4.3 Parallel and Multiphase Configurations To operate parallel and/or multiphase configurations, set the switches, cables, and wiri

Seite 32

Elgar CW-M Series 4.3.2 Setup for Six in Parallel Configuration 28

Seite 33 - 3.8 Parallel Connected Units

Elgar CW-M Series 4.3.3 Setup for Six-Phase Configuration 29

Seite 35 - 4 SET-UP

Elgar CW-M Series 4.3.4 Setup for Two-Phase Configuration 30

Seite 36

Elgar CW-M Series 4.3.5 Setup for Three-Phase Configuration 4.4 Setting the Phase Angle For multiphase operation, set switches 9 through 12 for the

Seite 37

Elgar CW-M Series This page intentionally left blank. 32

Seite 38

Elgar CW-M Series 5 OPERATION The controls and indicators for the CW series power source are detailed below. Refer to Figure 5–1. Figure 5–1 CW Fr

Seite 39

Elgar CW-M Series NUMERIC DISPLAY. This large, four-digit display, located in the voltage cluster, is a digital voltmeter that measures and displays t

Seite 40

Elgar CW-M Series q FAULT LAMP When lit, this lamp indicates that a fault condition has been detected, and that the system output has been turned of

Seite 41 - 4.4 Setting the Phase Angle

Elgar CW-M Series • Phase slaves display their phase angle instead of frequency. The phase master displays the system frequency. • Each unit in the

Seite 42

Elgar CW-M Series 6 MAINTENANCE 6.1 Periodic Service No routine maintenance on the CW Series unit is required, aside from periodic cleaning. Once a u

Seite 43 - 5 OPERATION

Elgar CW-M Series This page intentionally left blank. 38

Seite 44

ELGAR ONE–YEAR WARRANTY Elgar Electronics Corporation (hereinafter referred to as Elgar) warrants its products to be free from defects in material a

Seite 45

ii This page intentionally left blank.

Seite 46 - 5.2 Remote Control Signals

SAFETY NOTICE Before applying power to the system, verify that the instrument is configured properly for the user’s particular application. WARN

Seite 47 - 6 MAINTENANCE

iv SAFETY SYMBOLS CAUTIONRisk of Electrical ShockCAUTIONRefer to Accompanying DocumentsOff (Supply)Standby (Supply)On (Supply)Direct Current (DC)Alte

Seite 48