CW-P SERIES
PROGRAMMABLE
AC POWER SOURCE
Operation Manual
October 2013 Document No. M161691-01 Rev K
This manual covers models:
CW 801P
CW 1251P
CW 2501P
CW 801PH
CW 1251PH
CW 2501PH
CW 801PV
CW 1251PV
CW 2501PV
Seitenansicht 0
1 2 3 4 5 6 ... 61 62

Inhaltsverzeichnis

Seite 1 - AC POWER SOURCE

Contact Information Telephone: 800 733 5427 (toll free in North America) 858 450 0085 (direct) Fax: 858 458 0267 E

Seite 2

Contents Elgar CW-P Series vi Operation Manual 3.8 Remote Control Signal ...

Seite 3

Elgar CW-P Series Contents Operation Manual vii 5.3.11 RMS Voltage Loop ... 4-8 5.3.1

Seite 4

Contents Elgar CW-P Series viii Operation Manual LIST OF TABLES Table 3–1 Recommended Wire Gauge Selection Guide ...

Seite 5

Operation Manual 0-1 SECTION 0 INTRODUCTION Elgar's ContinuousWave™ (CW) Series power sources deliver 800 VA or 1250 VA in a 2U high (3.5 inche

Seite 6

Introduction Elgar CW-P Series 0-2 Operation Manual • 1 phase 45 to 500 Hz AC output; 45-1000 Hz with H–Option. Units may be connected in multipha

Seite 7 - SAFETY SYMBOLS

Operation Manual 1-1 SECTION 1 SPECIFICATIONS 1.1 Output POWER CW 801P 800 VA CW 1251P 1250 VA CW 2501P 2500 VA Power Factor of Load 0 lag to

Seite 8

Specifications Elgar CW-P Series 1-2 Operation Manual Total Harmonic Distortion 0.65% maximum up to 60 Hz; add 0.05%/10 Hz from 60 Hz to 100 Hz; a

Seite 9 - CONTENTS

Elgar CW-P Series Specifications Operation Manual 1-3 PHASE Range -359 to +359 degrees Positive phase indicates time lag from reference Accuracy

Seite 10 - Contents Elgar CW-P Series

Specifications Elgar CW-P Series 1-4 Operation Manual PEAK INRUSH CURRENT* (Available in Remote Mode only) Range CW 801P 0 to 25A CW 1251P 0

Seite 11 - Operation Manual

Elgar CW-P Series Specifications Operation Manual 1-5 POWER FACTOR* Range 0 to 1 Accuracy ±4% of range for linear loads, typical; at >10% of p

Seite 13 - INTRODUCTION

Specifications Elgar CW-P Series 1-6 Operation Manual 1.4 Protection Overcurrent: Shutdown mode Accuracy: +/- 1% of full scale, for linear loads w

Seite 14 - 0-2 Operation Manual

Elgar CW-P Series Specifications Operation Manual 1-7 SHIPPING WEIGHT CW 801P: 55.25 lbs. (25 kg) CW 1251P: 60.25 lbs. (27 kg) CW 2501P: 93.25

Seite 15 - SPECIFICATIONS

Specifications Elgar CW-P Series 1-8 Operation Manual This page intentionally left blank.

Seite 16 - 1-2 Operation Manual

Operation Manual 2-1 SECTION 2 INSTALLATION The Elgar CW series power supply has been fully calibrated and tested prior to shipment. The instrument

Seite 17 - 1.2 Measurement

Installation Elgar CW-P Series 2-2 Operation Manual 2.2 Wire Gauge Selection The following guidelines assist in determining the optimum cable speci

Seite 18 - 1-4 Operation Manual

Elgar CW-P Series Installation Operation Manual 2-3 The following notes apply to Table 3–1 and to the power cable definition: 1. The above figures

Seite 19 - 1.3 Input

Installation Elgar CW-P Series 2-4 Operation Manual 4. Derate the above wire gauge (use a heavier gauge) for higher environmental temperatures sinc

Seite 20 - 1.6 General

Elgar CW-P Series Installation Operation Manual 2-5 2.3 Mounting Instructions Refer to Figure 3–1 through Figure 3–4 for mounting dimensions and o

Seite 21 - 1.7 Options and Accessories

Installation Elgar CW-P Series 2-6 Operation Manual Figure 3–2 Mounting Dimensions, Front and Rear Views (CW 801P, CW 1251P)

Seite 22 - 1-8 Operation Manual

Elgar CW-P Series Installation Operation Manual 2-7 Figure 3–3 Mounting Dimensions, Front and Rear Views (CW 2501P)

Seite 24 - 2.2 Wire Gauge Selection

Installation Elgar CW-P Series 2-8 Operation Manual Figure 3–4 Mounting Dimensions, Top and Side Views (CW 801P and CW 1251P)

Seite 25 - Operation Manual 2-3

Elgar CW-P Series Installation Operation Manual 2-9 Figure 3–5 Mounting Dimensions, Top and Side Views (CW 2501P)

Seite 26 - 2-4 Operation Manual

Installation Elgar CW-P Series 2-10 Operation Manual 2.5 Power In Connections Connect input power to the INPUT terminal block on the rear panel as

Seite 27 - 2.4 Cooling

Elgar CW-P Series Installation Operation Manual 2-11 2.5.2 Split-Phase Supply Connections 120–0–120V 1. Remove the protective cover from the term

Seite 28 - 2-6 Operation Manual

Installation Elgar CW-P Series 2-12 Operation Manual 2.6 Power Out Connections 1. Remove the protective cover from the terminal block. 2. A facto

Seite 29 - Operation Manual 2-7

Elgar CW-P Series Installation Operation Manual 2-13 2.7 Sense Connections The CW Series unit can be used with or without remote sense leads conn

Seite 30 - 2-8 Operation Manual

Installation Elgar CW-P Series 2-14 Operation Manual To utilize remote sensing at the user's load, follow these steps: 1. Remove the protecti

Seite 31 - Operation Manual 2-9

Elgar CW-P Series Installation Operation Manual 2-15 2.8 Remote Control Signal Remote control allows you to set output voltage, lock to an externa

Seite 32 - 2.5 Power In Connections

Installation Elgar CW-P Series 2-16 Operation Manual 2.8.3 Sync Output Pulse • Set direction of Clock to ‘OUT’ (see Section 5.3.9). • Sync can be

Seite 33 - Operation Manual 2-11

Elgar CW-P Series Installation Operation Manual 2-17 6. Power up all CW units simultaneously, and ensure that each unit is reporting its address p

Seite 35 - 2.7 Sense Connections

Installation Elgar CW-P Series 2-18 Operation Manual Setup 1–Phase Master/Slave Pair Using Menu System 1. Ensure load wiring is removed from the tw

Seite 36 - 2-14 Operation Manual

Elgar CW-P Series Installation Operation Manual 2-19 24. Connect the Elgar cable 890-499-00 between the master “M/S OUT” and the slave “M/S IN” co

Seite 37 - 2.8 Remote Control Signal

Installation Elgar CW-P Series 2-20 Operation Manual 2.9.2 Setup for Three–Phase, Two Units per Phase Figure 3–12 Wiring Diagram for Three Phase,

Seite 38 - 2-16 Operation Manual

Elgar CW-P Series Installation Operation Manual 2-21 Setup Six CW Units as 3–Phase Master/Slave Set using Menu System 1. Ensure load wiring is rem

Seite 39 - Operation Manual 2-17

Installation Elgar CW-P Series 2-22 Operation Manual 26. Rotate the right knob until the right display reads “A”. 27. Press the ENTER/SAVE button.

Seite 40 - 2-18 Operation Manual

Elgar CW-P Series Installation Operation Manual 2-23 54. On the C slave CW press the ENTER/SAVE button. 55. Rotate the left knob until the left d

Seite 41 - Operation Manual 2-19

Installation Elgar CW-P Series 2-24 Operation Manual This page intentionally left blank.

Seite 42 - 2-20 Operation Manual

Operation Manual 3-1 SECTION 3 OPERATION This section details the front panel operations of the CW series power source, including the initializatio

Seite 43 - Operation Manual 2-21

Operation Elgar CW-P Series 3-2 Operation Manual Numeric Display. The large, four-digit display in the VOLTAGE/POWER section is a digital voltmeter

Seite 44 - 2-22 Operation Manual

Elgar CW-P Series Operation Operation Manual 3-3 ESCAPE Button. Press this button to exit the Menu function without saving parameter changes. Note

Seite 45 - Operation Manual 2-23

i About AMETEK AMETEK Programmable Power, Inc., a Division of AMETEK, Inc., is a global leader in the design and manufacture of precision, programm

Seite 46 - 2-24 Operation Manual

Operation Elgar CW-P Series 3-4 Operation Manual  OUTPUT Section This section is used to open and close the output relay. Output terminals are av

Seite 47 - OPERATION

Elgar CW-P Series Operation Operation Manual 3-5 Enter the menu system, detailed in Section 5.3, by pressing the ENTER/SAVE button once. After displ

Seite 48 - 3-2 Operation Manual

Operation Elgar CW-P Series 3-6 Operation Manual 3.4 Programmed Frequency Steps The allowed frequency delta for programmed frequency steps is a fun

Seite 49 - Operation Manual 3-3

Operation Manual 4-1 SECTION 4 PROGRAMMING 4.1 Programming the CW Via the Front Panel Press the PROGRAM button in the VOLTAGE/POWER section to ent

Seite 50 -  OUTPUT Section

Programming Elgar CW-P Series 4-2 Operation Manual 4.1.1 VOLTAGE/POWER Section To change the voltage range from High to Low or vice-versa, press th

Seite 51 - 3.3 Power Up

Elgar CW-P Series Programming Operation Manual 4-3 When the left MEASURE and the WATTS LEDs are illuminated, the wattage being sourced at the output

Seite 52 - 3-6 Operation Manual

Programming Elgar CW-P Series 4-4 Operation Manual 4.3 Menu Operations There are two buttons in the Menu section of the front panel, ENTER/SAVE and

Seite 53 - PROGRAMMING

Elgar CW-P Series Programming Operation Manual 4-5 The Menu LED is used to indicate if changes have been introduced into the menu system. If there h

Seite 54 - 4.2 Measurement Operations

Programming Elgar CW-P Series 4-6 Operation Manual 4.3.3 Specify Current Limit Type This menu item specifies whether the CW will shut down after a

Seite 55 - Operation Manual 4-3

Elgar CW-P Series Programming Operation Manual 4-7 4.3.7 Recall Machine Settings This menu item, when saved (not cancelled) by the user, will recal

Seite 56 - 4.3 Menu Operations

ii This page intentionally left blank.

Seite 57 - Operation Manual 4-5

Programming Elgar CW-P Series 4-8 Operation Manual 4.3.11 RMS Voltage Loop This entry specifies whether the RMS voltage loop is on or off. When the

Seite 58 - 4-6 Operation Manual

Operation Manual 5-1 SECTION 5 MAINTENANCE 5.1 Periodic Service No routine maintenance on the CW Series unit is required, aside from periodic clea

Seite 59 - Operation Manual 4-7

Maintenance Elgar CW-P Series 5-2 Operation Manual This page intentionally left blank.

Seite 60 - 4-8 Operation Manual

iii Important Safety Instructions Before applying power to the system, verify that your product is configured properly for your particular applicat

Seite 61 - MAINTENANCE

iv Product Family: CW801P, CW1251P, CW2501P, CW801P-H, CW1251P-H, CW2501P-H, CW801P-V, CW1251P-V, CW2501P-V Warranty Period: One Year WARRANTY TERMS

Seite 62 - 5-2 Operation Manual

Operation Manual v CONTENTS SECTION 1 INTRODUCTION ................ 0-1 SECTION 2 SPECIFICATIONS ..

Kommentare zu diesen Handbüchern

Keine Kommentare